Full metadata record
DC FieldValueLanguage
dc.creatorMoreno-Montañes, J. (Javier)-
dc.creatorAlvarez-Vidal, A. (Aurora)-
dc.creatorSainz-Gomez, C. (C.)-
dc.creatorRodriguez-Conde, R.M. (R. M.)-
dc.date.accessioned2012-10-11T16:45:31Z-
dc.date.available2012-10-11T16:45:31Z-
dc.date.issued2002-
dc.identifier.citationMoreno-Montanes J, Alvarez-Vidal A, Sainz Gomez C, Rodriguez Conde R. Capa de fibras nerviosas en ojos glaucomatosos. Estudio realizado mediante OCT y su comparación con el campo visual. Arch Soc Esp Oftalmol 2002 Aug;77(8):435-441.es_ES
dc.identifier.issn0365-6691-
dc.identifier.urihttps://hdl.handle.net/10171/23355-
dc.description.abstractTo investigate the retinal nerve fiber layer (RNFL) thickness in glaucomatous eyes using Optical Coherence Tomography (OCT). To compare the RNFL thickness with visual field damage (Humphrey field analyzer). MATERIAL AND METHODS: The mean RNFL thickness in glaucomatous eyes (n = 80) was compared with age-matched normal eyes (n = 40). Three circular scans were obtained for each eye using OCT (3.4 mm diameter). In each eye, average RNFL, 4 quadrants and 12 meridians were calculated and compared. The superior-inferior asymmetry of RNFL was studied. The average RNFL thickness was compared with mean deviation (MD) and mean standard deviation (MSD) of SITA 24-2 visual field program. RESULTS: Mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes (p<0.001). The RNFL thickness was decrease in the 4 quadrants and 11 of 12 meridians studied in glaucomatous eyes (p<0.05). The superior-inferior asymmetry showed a significant difference in RNFL thickness at 30 degrees central meridian (p<0.05). Mean RNFL thickness was significantly associated with DM and DSM of visual field (p<0.001) in glaucomatous eyes. CONCLUSIONS: OCT revealed significant quantitative differences in RNFL thickness between glaucomatous and normal eyes. OCT showed a considerable measurements overlap between glaucomatous and normal eyes, which can limit the sensitivity and specificity of this instrumentes_ES
dc.language.isospaes_ES
dc.publisherElsevier Españaes_ES
dc.rightsinfo:eu-repo/semantics/closedAccess-
dc.subjectGlaucoma/pathologyes_ES
dc.subjectRetina/pathologyes_ES
dc.subjectVisual Fieldses_ES
dc.titleCapa de fibras nerviosas en ojos glaucomatosos. Estudio realizado mediante OCT y su comparación con el campo visuales_ES
dc.title.alternativeRetinal nerve fiber layer thickness in glauccomatous eyes. A comparative study between OCT and visual fieldes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttp://www.oftalmo.com/seo/archivos/articulo.php?idSolicitud=1060&numR=8&mesR=8&anioR=2002&idR=61es_ES
dc.type.driverinfo:eu-repo/semantics/articlees_ES

Files in This Item:
There are no files associated with this item.


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.