Full metadata record
DC FieldValueLanguage
dc.creatorRemiro, R. (Rebeca)-
dc.creatorIbañez-Vea, M. (María)-
dc.creatorGonzalez-Peñas, E. (Elena)-
dc.creatorLizarraga, E. (Elena)-
dc.date.accessioned2014-09-15T14:43:44Z-
dc.date.available2014-09-15T14:43:44Z-
dc.date.issued2010-
dc.identifier.citationRemiro R, Ibáñez-Vea M, González-Peñas E, Lizarraga E. Validation of a liquid chromatography method for the simultaneous quantification of ochratoxin A and its analogues in red wines. J Chromatogr A 2010 Dec;24;1217(52):8249-8256es_ES
dc.identifier.issn0021-9673-
dc.identifier.urihttps://hdl.handle.net/10171/36579-
dc.description.abstractA validated high-performance liquid chromatography (HPLC) method with fluorescence detection for the simultaneous quantification of ochratoxin A (OTA) and its analogues (ochratoxin B (OTB), ochratoxin C (OTC) and methyl ochratoxin A (MeOTA)) in red wine at trace levels is described. Before their analysis by HPLC-FLD, ochratoxins were extracted and purified with immunoaffinity columns from 50 mL of red wine at pH = 7.2. Validation of the analytical method was based on the following parameters: selectivity, linearity, robustness, limits of detection and quantification, precision (within-day and between-day variability), recovery and stability. The limits of detection (LOD) in red wine were established at 0.16, 0.32, 0.27 and 0.17 ng L-1 for OTA, OTB, MeOTA and OTC, respectively. The limit of quantification (LOQ) was established as 0.50 ng L-1 for all of the ochratoxins. The LOD and LOQ obtained are the lowest found for OTA in the reference literature up to now. Recovery values were 93.5, 81.7, 76.0 and 73.4% for OTA, OTB, MeOTA and OTC, respectively. For the first time, this validated method permits the investigation of the co-occurrence of ochratoxins A, B, C and methyl ochratoxin A in 20 red wine samples from Spain.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectOchratoxin Aes_ES
dc.subjectOchratoxin analogueses_ES
dc.subjectWinees_ES
dc.subjectSimultaneous validationes_ES
dc.subjectHPLCes_ES
dc.titleValidation of a liquid chromatography method for the simultaneous quantification of ochratoxin A and its analogues in red wineses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.identifier.doihttp://dx.doi.org/10.1016/j.chroma.2010.11.004es_ES

Files in This Item:
Thumbnail
File
validacion OTs vinos.pdf
Description
Size
195.73 kB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.