Full metadata record
DC FieldValueLanguage
dc.creatorDiez-Goñi, N. (Nieves)-
dc.creatorPacheco, S. (Sofía)-
dc.creatorLlorente-Ortega, M. (Marcos)-
dc.creatorFernández-González, S. (Secundino)-
dc.date.accessioned2023-12-22T13:45:57Z-
dc.date.available2023-12-22T13:45:57Z-
dc.date.issued2020-
dc.identifier.citationDiez-Goñi, N. (Nieves); Pacheco, S. (Sofía); Llorente-Ortega, M. (Marcos); et al. "Validation of a sensor-fitted simulator for upper airway examination". Otolaryngology-Head and Neck Surgery. 164 (2), 2020, 339 - 345es
dc.identifier.issn0194-5998-
dc.identifier.urihttps://hdl.handle.net/10171/68179-
dc.description.abstractObjective: To validate a simulator for upper airway examination, fitted with sensors, for use as an academic tool for learning how to conduct examination of the upper airway and for evaluation of that learning. Study design: Validation study. Setting: Undergraduate medical education. Subjects and methods: A group of 18 fifth-year medical students and another of 6 otorhinolaryngology specialists conducted 6 examinations each with the simulator. To investigate concurrent validity, we calculated the correlation between damage scores provided by the simulator and damage assessment by a specialist. To evaluate construct validity, we compared both groups with regard to damage scores, technical procedure, and time spent. To examine content and face validity, we used questionnaires based on a 5-point Likert scale. Results: For concurrent validity, the correlation between the simulator's damage scores and the specialist's damage assessment was high: Spearman's ρ was 0.828 (P < .001). For construct validity, the group of students differed from the group of specialists in damage scores (P = .027) and in technical procedures (P < .001) but not in time spent. For content validity, all questionnaire statements were scored highly, and both groups had similar average scores. For face validity, the group of specialists considered the simulator to be realistic, and all statements on the questionnaire were rated with at least 4/5. Conclusion: Concurrent, construct, content, and face validity have been demonstrated for a sensor-fitted simulator for upper airway examination, which is therefore accurate enough to be used as an academic tool for learning and evaluation of learning.es_ES
dc.language.isoenges_ES
dc.publisherWileyes_ES
dc.rightsinfo:eu-repo/semantics/closedAccesses_ES
dc.subjectConcurrent validityes_ES
dc.subjectConstruct validityes_ES
dc.subjectContent validityes_ES
dc.subjectFace validityes_ES
dc.subjectFlexible endoscopees_ES
dc.subjectSimulationes_ES
dc.subjectUpper airway examinationes_ES
dc.titleValidation of a sensor-fitted simulator for upper airway examinationes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.identifier.doi10.1177/0194599820941017-
dadun.citation.endingPage345es_ES
dadun.citation.number2es_ES
dadun.citation.publicationNameOtolaryngology-Head and Neck Surgeryes_ES
dadun.citation.startingPage339es_ES
dadun.citation.volume164es_ES

Files in This Item:
File
Validation of a Sensor-Fitted Simulator for Upper Airway Examination.pdf
Description
Size
3.62 MB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.