Calvo, R. (R.)
- Publications
- item.page.relationships.isContributorAdvisorOfPublication
- item.page.relationships.isContributorOfPublication
3 results
Search Results
Now showing 1 - 3 of 3
- Utilización de un ciclotrón para la producción de radionucleidos emisores de positrones(Garsi, 1999) Gamez, C. (C.); Marti-Climent, J.M. (Josep María); Peñuelas-Sanchez, I. (Ivan); Calvo, R. (R.); Richter, J.A. (José Ángel); Gimenez, M. (M.)The experience acquired by our center during the first two years of using cyclotron 18/9 (IBA) dedicated to the production of clinical positron emission radionuclides is described. The cyclotron performance characteristics, production yields, quality control and synthesized radiotracers are analyzed. Cyclotron makes it possible to produce up to 3,300 mCi of 18F-, 270 mCi of 18F2, 3,100 mCi of 11C, 502 mCi of 13N (in 120, 60, 35 and 20 minutes respectively) and 540 mCi/min of 15O. In our center, about 85% of the PET studies are performed with 18F-FDG, whereas the remaining are done with 15O-water, 11C-bicarbonate, 11C-methionine, 13N-ammonia or 18F-. Cyclotron is included in the Radiopharmacy Unit of our PET facility and is subjected to a global quality control program. Follow-up of the bombardment parameters and periodic verifications of the cyclotron performance have made it possible to prevent equipment functioning problems, increase mean time between stoppage and decrease downtime. We conclude that cyclotron has high production capabilities and allows enough flexibility for a clinical and research positron emission tomography center; furthermore, it can also be used for regional distribution of 18F-FDG to satellite PET centers.
- Long term evaluation of high tibial valgus osteotomy(Springer Verlag, 1990) Cañadell, J.M. (J. M.); Lopez, R. (R.); Calvo, R. (R.); Valenti-Nin, J.R. (Juan Ramón)We present a long term evaluation of 100 high valgus tibial osteotomies with a mean follow up of 11 years. Knees with slight or moderate osteoarthritis had the best results. Slight overcorrection was beneficial, but gross overcorrection was not. There were few complications and the overall long term results were goo
- Aloinjertos en artrodesis vertebrales extensas(Universidad de Navarra, 1996) Calvo, R. (R.); Mora, G. (Gonzalo); Beguiristain-Gurpide, J.L. (José Luis); Baldes, G. (G.); Villas-Tome, C. (Carlos)La cirugía de las deformidades, fracturas y tumores vertebrales requiere frecuentemente artrodesis amplias, lo cual conlleva la dificultad de obtener suficiente injerto óseo autólogo (particularmente en niños y en casos de deformidades paralíticas) y la necesidad de una segunda incisión, con el consiguiente aumento del tiempo quirúrgico y eventual morbilidad. Estudiamos 52 pacientes afectos de deformidades, fracturas o tumores vertebrales que fueron intervenidos mediante artrodesis vertebral extensa, en los que se utilizó aloinjerto de cabeza femoral como hueso esponjoso para aumentar la cantidad obtenida del propio lecho de artrodesis (estructuras posteriores). Además, en tres ocasiones se utilizó como injerto óseo intersomático un fragmento de cabeza femoral tallado a medida, realizándose una costotransversectomía para su colocación. El seguimiento fue entre 1 y 4 años. La única complicación observada fue la aparición de seromas de resolución espontánea en los 15 primeros casos. Posteriormente este problema se evitó con el lavado repetido del injerto, una vez triturado, con suero fisiológico caliente. En nuestra experiencia, la utilización de aloinjertos óseos permitió disminuir el tiempo quirúrgico de las intervenciones y a su vez evitar nuevas incisiones, sin reducir se las posibilidades de obtener una correcta artrodesis vertebral.