Martínez-Lage, A. (Adriana)

Search Results

Now showing 1 - 1 of 1
  • Thumbnail Image
    Long-term results of intraoperative multicatheter breast implant (IOMBI) for accelerated partial breast irradiation (APBI) on early breast cancer patients
    (Elsevier, 2024) Martinez-Monge, R. (Rafael); Blanco, J. (Javier); Martinez-Regueira, F. (Fernando); Rodriguez-Spiteri, N. (Natalia); Jablonska, P.A. (Paola Anna); Elizalde, A. (Arlette); Pina-Insausti, L. (Luis); Abengozar-Muela, M. (Marta); Cambeiro, M. (Mauricio); Olartecoechea, B. (Begoña); Gimeno-Morales, M. (Marta); Ramos, L. (Luis); Martínez-Lage, A. (Adriana)
    Background and purpose: Multicatheter breast brachytherapy is a standard technique for accelerated partial breast irradiation (APBI) in early breast cancer patients. Intraoperative multicatheter breast implant (IOMBI) followed by perioperative high-dose-rate brachytherapy (PHDRBT) offers a novel and advantageous approach. We present long-term oncological, toxicity, and cosmesis outcomes for a well-experienced single institution. Materials and methods: Eligible women aged ≥ 40 years with clinically and radiologically confirmed unifocal invasive or in situ ≤ 3 cm breast tumors underwent IOMBI during breast-conserving surgery. Patients meeting APBI criteria by definitive pathologic results received 3.4 Gy × 10fx with PHDRBT. Patients not suitable for APBI received PHDRBT-boost followed by WBRT. Results: A total of 171 patients underwent IOMBI during BCS, 120 patients (70.1 %) were suitable for APBI and 51 (29.8 %) for anticipated PHDRBT-boost. The median age was 61 years (range: 40-78), the median tumor size was 1.1 cm (range: 0.2-3.5), with a histological diagnosis of invasive ductal carcinoma in 78.9 % and ductal in situ in 21.1 %. A median of 9 catheters (range: 4-14) were used. For APBI, the median CTV and V100 were 40.8 cc (range: 8.6-99) and 35.4 cc (range: 7.2-94). The median of healthy breast tissue irradiated represents 7.2 % (range: 2.3-28 %) and the median local treatment duration was 10 days (range: 7-16). With a median follow-up of 8.8 years (range: 0.3-16.25), the 8-year local, locoregional, and distant control rates were 99 %, 98.1 %, and 100 %. G1-G2 late-toxicity rate was 53.4 %. Long-term cosmetic evaluation was excellent-good in 90.8 %. Conclusion: IOMBI&PHDRBT program reports excellent long-term oncological outcomes, with a reduction from unnecessary irradiation exposure which translates into low long-term toxicity and good cosmesis outcomes, especially on well-selected APBI patients.