Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Domínguez, P. (Pilar) | - |
dc.creator | Fernandez-Alvarez, J.M. (José María) | - |
dc.creator | Tuñón-Blanco, P. (Paulino) | - |
dc.creator | O'Kennedy, R. (Richard) | - |
dc.creator | Smyth, M.R. (Malcolm Rowland) | - |
dc.date.accessioned | 2020-03-30T06:58:48Z | - |
dc.date.available | 2020-03-30T06:58:48Z | - |
dc.date.issued | 1990-01-04 | - |
dc.identifier.citation | Dominguez P (Pilar), Fernandez Alvarez JM (José María), Tuñon Blanco P (Paulino), O'Kennedy R (Richard), Smyth MR (Malcolm Rowland). "Flow-Injection Analysis of Hydrogen Peroxide Using a Horseradish Peroxidase-Modified Electrode Detection System" en "Papers presented at the Bioelectrochemistry and Bioelectronics Workshop", Oxford (U.K.), 04-05-01-1990. | es_ES |
dc.identifier.uri | https://hdl.handle.net/10171/58914 | - |
dc.description.abstract | A flow-injection analysis (FIA) system utilizing a horseradish peroxidase-modified amperometric electrode is described. The enzyme was immobilized through adsorption onto a glassy carbon electrode and the system is used to determine hydrogen peroxide at submicromolar levels. | es_ES |
dc.description.sponsorship | P. Dominguez thanks the European Community, for a grant under the ERASMUS Program. J. M. Fernandez thanks the Spanish Ministry of Education for a post-doctoral grant. | es_ES |
dc.language.iso | eng | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | Flow injection analysis | es_ES |
dc.subject | Hidrogen peroxide | es_ES |
dc.subject | Horseradish perosidase | es_ES |
dc.subject | Adsorption | es_ES |
dc.title | Flow-Injection Analysis of Hydrogen Peroxide Using a Horseradish Peroxidase-Modified Electrode Detection System | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.publisher.place | Oxford, UK | es_ES |
Files in This Item:
Statistics and impact