Consensus‑based technical recommendations for clinical translation of renal ASL MRI
Keywords: 
MRI
Arterial spin labelling
Kidney
Perfusion
Renal blood fow
Issue Date: 
2020
ISSN: 
0968-5243
Note: 
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativeco mmons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Citation: 
Nery, F. (Fabio); Buchanan, C.E. (Charlotte E.); Harteveld, A.A. (Anita A.); et al. "Consensus‑based technical recommendations for clinical translation of renal ASL MRI". Magnetic Resonance Materials in Physics, Biology and Medicine. 33, 2020, 141 - 161
Abstract
Objectives This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T feld strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. Methods An international panel of 23 renal ASL experts followed a modifed Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. Results Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or fow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantifcation model. Discussion This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.

Files in This Item:
Thumbnail
File
s10334-019-00800-z.pdf
Description
Size
2.16 MB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.