Full metadata record
DC FieldValueLanguage
dc.creatorTamames-Tabar, C. (Cristina)-
dc.creatorImbuluzqueta, E. (Edurne)-
dc.creatorCampanero, M.A. (Miguel Angel)-
dc.creatorHorcajada, P. (Patricia)-
dc.creatorBlanco-Prieto, M.J. (María José)-
dc.date.accessioned2013-12-23T15:25:22Z-
dc.date.available2013-12-23T15:25:22Z-
dc.date.issued2013-
dc.identifier.citationTamames-Tabar C, Imbuluzqueta E, Campanero MA, Horcajada P, Blanco-Prieto MJ. A simple and robust high-performance liquid chromatography coupled to a diode-array detector method for the analysis of genistein in mouse tissues. J Chromatogr B 2013 SEP 15;935:47-53es_ES
dc.identifier.issn1570-0232-
dc.identifier.urihttps://hdl.handle.net/10171/34790-
dc.description.abstractA simple liquid-liquid extraction procedure and quantification by high-performance liquid chromatography (HPLC) method coupled to a diode-array detector (DAD) of genistein (GEN) was developed in various mouse biological matrices. 7-ethoxycoumarin was used as internal standard (IS) and peaks were optimally separated using a Kinetex C18 column (2.6 µm, 150 mm X 2.10 mm I.D.) at 40 ºC with an isocratic elution of mobile phase with sodium dihydrogen phosphate 0.01M in water at pH 2.5 and methanol (55:45, v/v), at a flow rate of 0.25 mL/min. The injection volume was 10 µL. In all cases, the range of GEN recovery was higher than 61%. The low limit of quantification (LLOQ) was 25 ng/mL. The linearity of the calibration curves was satisfactory in all cases as shown by correlation coefficients >0.996. The within-day and between-day precisions were <15% and the accuracy ranged in all cases between 90.14 and 106.05%. This method was successfully applied to quantify GEN in liver, spleen, kidney and plasma after intravenous administration of a single dose (30 mg/Kg) in female BALB/C mice.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectGenisteines_ES
dc.subjectHPLCes_ES
dc.subjectExtraction methodes_ES
dc.subjectBiological matriceses_ES
dc.subjectMethod validationes_ES
dc.titleA simple and robust high-performance liquid chromatography coupled to a diode-array detector method for the analysis of genistein in mouse tissueses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.identifier.doihttp://dx.doi.org/10.1016/j.jchromb.2013.07.020-

Files in This Item:
Thumbnail
File
A SIMPLE AND ROBUST HIGH.pdf
Description
Size
166.6 kB
Format
Adobe PDF
Thumbnail
File
Tables-Tamames-Tabar et al 2013.pdf
Description
Size
65.31 kB
Format
Adobe PDF
Thumbnail
File
Tamames-Tabar et al-Fig 1.pdf
Description
Size
12.51 kB
Format
Adobe PDF
Thumbnail
File
Tamames-Tabar et al-Fig 2.pdf
Description
Size
109.57 kB
Format
Adobe PDF
Thumbnail
File
Tamames-tabar et al-Fig 3.pdf
Description
Size
113.75 kB
Format
Adobe PDF
Thumbnail
File
Tamames-tabar et al-Fig 4.pdf
Description
Size
124.68 kB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.