dc.creatorGonzalez-Hernandez, A. (Alvaro)-
dc.creatorAlegre-Martinez, E. (Estibaliz)-
dc.creatorFernández-Calle, P. (Pilar)-
dc.creatorVaro, N. (Nerea)-
dc.creatorCalleja-Aznárez, S. (Sofía)-
dc.date.accessioned2024-01-16T13:15:39Z-
dc.date.available2024-01-16T13:15:39Z-
dc.date.issued2022-
dc.identifier.citationGonzalez-Hernandez, A. (Alvaro); Alegre-Martinez, E. (Estibaliz); Fernández-Calle, P. (Pilar); et al. "Impact of ultra-low temperature long-term storage on the preanalytical variability of twentyone common biochemical analytes". Clinical Chemistry and Laboratory Medicine (CCLM). 60 (7), 2022, 1003 - 1010es_ES
dc.identifier.urihttps://hdl.handle.net/10171/68378-
dc.description.abstractObjectives: Retrospective studies frequently assume analytes long-term stability at ultra-low temperatures. However, these storage conditions, common among biobanks and research, may increase the preanalytical variability, adding a potential uncertainty to the measurements. This study is aimed to evaluate long-term storage stability of different analytes at <−70 °C and to assess its impact on the reference change value formula. Methods: Twenty-one analytes commonly measured in clinical laboratories were quantified in 60 serum samples. Samples were immediately aliquoted and frozen at <−70 °C, and reanalyzed after 11 ± 3.9 years of storage. A change in concentration after storage was considered relevant if the percent deviation from the baseline measurement was significant and higher than the analytical performance specifications. Results: Preanalytical variability (CVP) due to storage, determined by the percentage deviation, showed a noticeable dispersion. Changes were relevant for alanine aminotransferase, creatinine, glucose, magnesium, potassium, sodium, total bilirubin and urate. No significant differences were found in aspartate aminotransferase, calcium, carcinoembryonic antigen, cholesterol, C-reactive protein, direct bilirubin, free thryroxine, gammaglutamyltransferase, lactate dehydrogenase, prostatespecific antigen, triglycerides, thyrotropin, and urea. As nonnegligible, CVP must remain included in reference change value formula, which was modified to consider whether one or two samples were frozen. Conclusions: After long-term storage at ultra-low temperatures, there was a significant variation in some analytes that should be considered. We propose that reference change value formula should include the CVP when analyzing samples stored in these conditions.es_ES
dc.description.sponsorshipRoche Diagnosticses_ES
dc.language.isospaes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBiobankes_ES
dc.subjectLong-term storagees_ES
dc.subjectMagnitude stabilityes_ES
dc.subjectPreanalytical variabilityes_ES
dc.subjectReference change valuees_ES
dc.subjectUltralow temperatureses_ES
dc.titleImpact of ultra-low temperature long-term storage on the preanalytical variability of twentyone common biochemical analyteses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dadun.citation.endingPage1010es_ES
dadun.citation.number7es_ES
dadun.citation.publicationNameClinical Chemistry and Laboratory Medicine (CCLM)es_ES
dadun.citation.startingPage1003es_ES
dadun.citation.volume60es_ES