Ultra high performance liquid chromatography–tandem mass spectrometry method for cyclosporine a quantification in biological samples and lipid nanosystems
Keywords: 
Biodistribution
Pharmacokinetics
Lipid nanocarriers
UHPLC–tandem mass spectrometry
Cyclosporine A
Issue Date: 
2013
Publisher: 
Elsevier
ISSN: 
1570-0232
Citation: 
Guada M, Imbuluzqueta E, Estella-Hermoso de Mendoza A, Lana H, Dios-Viéitez MC, Blanco-Prieto MJ. Ultra high performance liquid chromatography–tandem mass spectrometry method for cyclosporine a quantification in biological samples and lipid nanosystems. J Chromatogr B Analyt Technol Biomed Life Sci 2013 5/15;927(0):164-172
Abstract
Cyclosporine A (CyA) is an immunosuppressant cyclic undecapeptide used for the prevention of organ transplant rejection and in the treatment of several autoimmune disorders. An ultra high performance liquid chromatography–tandem mass spectrometry method (UHPLC–MS/MS) to quantify CyA in lipid nanosystems and mouse biological matrices (whole blood, kidneys, lungs, spleen, liver, heart, brain, stomach and intestine) was developed and fully validated. Chromatographic separation was performed on an Acquity UPLC® BEH C18 column with a gradient elution consisting of methanol and 2 mM ammonium acetate aqueous solution containing 0.1% formic acid at a flow rate of 0.6 mL/min. Amiodarone was used as internal standard (IS). Retention times of IS and CyA were 0.69 min and 1.09 min, respectively. Mass spectrometer operated in electrospray ionization positive mode (ESI+) and multiple reaction monitoring (MRM) transitions were detected, m/z 1220.69 → 1203.7 for CyA and m/z 646 → 58 for IS. The extraction method from biological samples consisted of a simple protein precipitation with 10% trichloroacetic acid aqueous solution and acetonitrile and 5 μL of supernatant were directly injected into the UHPLC–MS/MS system. Linearity was observed between 0.001 μg/mL–2.5 μg/mL (r ≥ 0.99) in all matrices. The precision expressed in coefficient of variation (CV) was below 11.44% and accuracy in bias ranged from −12.78% to 7.99% including methanol and biological matrices. Recovery in all cases was above 70.54% and some matrix effect was observed. CyA was found to be stable in post-extraction whole blood and liver homogenate samples exposed for 6 h at room temperature and 72 h at 4 °C. The present method was successfully applied for quality control of lipid nanocarriers as well as in vivo studies in BALB/c mice.

Files in This Item:
Thumbnail
File
JCB-12-1034-Guada et al-manuscript_R1.pdf
Description
Size
133.81 kB
Format
Adobe PDF
Thumbnail
File
JCB-12-1034-Tables_R1.pdf
Description
Size
76.38 kB
Format
Adobe PDF
Thumbnail
File
JCB-12-1034-Figure 1_R1.tif
Description
Size
19.28 MB
Format
TIFF
Thumbnail
File
JCB-12-1034-Figure 2_R1.tif
Description
Size
9.93 MB
Format
TIFF
Thumbnail
File
JCB-12-1034-Figure 3_R1.tif
Description
Size
9.78 MB
Format
TIFF
Thumbnail
File
JCB-12-1034-Figure 4_R1.tif
Description
Size
9.37 MB
Format
TIFF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.