Full metadata record
DC FieldValueLanguage
dc.creatorMarti-Climent, J.M. (Josep María)-
dc.creatorPeñuelas-Sanchez, I. (Ivan)-
dc.creatorCalvo, R. (R.)-
dc.creatorGimenez, M. (M.)-
dc.creatorGamez, C. (C.)-
dc.creatorRichter, J.A. (José Ángel)-
dc.date.accessioned2014-04-02T16:17:22Z-
dc.date.available2014-04-02T16:17:22Z-
dc.date.issued1999-
dc.identifier.citationMartí-Climent J, Peñuelas I, Calvo R, Giménez M, Gámez C, Richter J. Utilización de un ciclotrón para la producción de radionucleidos emisores de positrones. Rev Esp Med Nucl. 1999 Aug;18(4):261-267es_ES
dc.identifier.issn0212-6982-
dc.identifier.urihttps://hdl.handle.net/10171/35631-
dc.description.abstractThe experience acquired by our center during the first two years of using cyclotron 18/9 (IBA) dedicated to the production of clinical positron emission radionuclides is described. The cyclotron performance characteristics, production yields, quality control and synthesized radiotracers are analyzed. Cyclotron makes it possible to produce up to 3,300 mCi of 18F-, 270 mCi of 18F2, 3,100 mCi of 11C, 502 mCi of 13N (in 120, 60, 35 and 20 minutes respectively) and 540 mCi/min of 15O. In our center, about 85% of the PET studies are performed with 18F-FDG, whereas the remaining are done with 15O-water, 11C-bicarbonate, 11C-methionine, 13N-ammonia or 18F-. Cyclotron is included in the Radiopharmacy Unit of our PET facility and is subjected to a global quality control program. Follow-up of the bombardment parameters and periodic verifications of the cyclotron performance have made it possible to prevent equipment functioning problems, increase mean time between stoppage and decrease downtime. We conclude that cyclotron has high production capabilities and allows enough flexibility for a clinical and research positron emission tomography center; furthermore, it can also be used for regional distribution of 18F-FDG to satellite PET centers.es_ES
dc.language.isospaes_ES
dc.publisherGarsies_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectCiclotrónes_ES
dc.subjectFuncionamientoes_ES
dc.subjectPETes_ES
dc.titleUtilización de un ciclotrón para la producción de radionucleidos emisores de positroneses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES

Files in This Item:
Thumbnail
File
revista espanola de medicina nuclear18_4_1999_261_267.pdf
Description
Size
295.93 kB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.