Clinical usefulness of abdominal bioimpedance (ViScan) in the determination of visceral fat and its application in the diagnosis and management of obesity and its comorbidities
Palabras clave : 
Bioimpedance
Body composition
Body fat
Obesity
Visceral fat.
Fecha de publicación : 
2018
Editorial : 
Elsevier
ISSN : 
0261-5614
Cita: 
Gomez-Ambrosi, J. (Javier); González-Crespo. I. (Ignacio); Catalan, V. (Victoria); et al. "Clinical usefulness of abdominal bioimpedance (ViScan) in the determination of visceral fat and its application in the diagnosis and management of obesity and its comorbidities". Clinical Nutrition. 37 (2), 2018, 580 - 589
Resumen
Background & aims: Visceral adipose tissue (VAT) has been shown to be profoundly responsible of most of the obesity-associated metabolic derangements. The measurement of VAT usually implies the use of imaging techniques such as magnetic resonance imaging or computed tomography (CT). Our aim was to evaluate the accuracy of the determination of VAT by means of abdominal bioimpedance (BIA) with the ViScan device in comparison with CT and its clinical usefulness in the management of obesity. Methods: We studied a sample of 140 subjects (73 males/67 females) with BMI ranging from 17.7 to 50.4 kg/m2 to evaluate the accuracy of the ViScan in comparison to CT to determine VAT. To further analyze ViScan's clinical usefulness we studied a separate cohort (n = 2849) analyzing cardiometabolic risk factors. Furthermore, we studied the ability of the ViScan to detect changes in VAT after weight gain (n = 107) or weight loss (n = 335). The study was performed from October 2009 through June 2015. Results: ViScan determines VAT with a good accuracy in individuals with a CT-VAT up to 200 cm2, and then with lower precision with increasing body mass, exhibiting a moderate-high correlation with CT-VAT (r = 0.75, P < 0.001). Importantly, VAT determination with the ViScan exhibits better correlations with several cardiometabolic risk factors such as glucose, triglycerides, HDL-cholesterol and markers of fatty liver than anthropometric measurements such as BMI or waist circumference. ViScan is able to detect VAT variations after body weight changes. Conclusions: Since the possibility of measuring VAT by imaging techniques is not always available, abdominal BIA represents a good alternative to estimate VAT, allowing the identification of patients with increased VAT-related cardiometabolic risk and a better management of obese patients.

Ficheros en este ítem:
Fichero
Clinical usefulness of abdominal bioimpedance (ViScan) in the determination of visceral fat and its application in the diagnosis and management of obesity and its comorbidities.pdf
Descripción
Tamaño
1.89 MB
Formato
Adobe PDF


Estadísticas e impacto
0 citas en
0 citas en

Los ítems de Dadun están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.