Full metadata record
DC FieldValueLanguage
dc.creatorGuijarro-Hernández, A. (Alberto)-
dc.creatorHurtado, C. (Cristina)-
dc.creatorMartinez-Irujo, J.J. (Juan José)-
dc.creatorVizmanos-Pérez, J.L. (José Luis)-
dc.date.accessioned2024-03-11T08:40:39Z-
dc.date.available2024-03-11T08:40:39Z-
dc.date.issued2023-
dc.identifier.citationGuijarro-Hernández, A. (Alberto); Hurtado, C. (Cristina); Martinez-Irujo, J.J. (Juan José); et al. "Monitoring Caenorhabditis elegans molting in a conventional luminometer". MethodsX. 10, 2023, 102235es
dc.identifier.issn10.1016/j.mex.2023.102235-
dc.identifier.issn2215-0161-
dc.identifier.urihttps://hdl.handle.net/10171/69226-
dc.description.abstractMolting is an essential developmental process in Caenorhabditis elegans. However, the study of molting in the worm has been limited by the lack of automated techniques that allow monitoring the process in a simple way. In 2015, Olmedo et al. published an automated method to monitor the timing of each larval stage and molt in C. elegans using bioluminescence. This new method has greatly contributed to the study of molting in this organism but requires the use of a highsensitivity luminometer, which many laboratories do not have. We have adapted the method to a conventional luminometer, so that it can be used by most laboratories that work with C. elegans and do not have high-sensitivity equipment. • A customization of a method to study molting in C. elegans using a conventional luminometer instead of a high-sensitivity one. • This adaptation allows most laboratories to use their routine luminometers to study molting in C. elegans. • Although the use of a high-sensitivity luminometer, as proposed by Olmedo et al., remains the gold standard for studying molting, this adaptation is suitable for studying significant differences in molting and the duration of larval stages between different strains of C. elegans.es_ES
dc.description.sponsorshipThis work was supported by the PIUNA 2020 Program of the University of Navarra [grant number 15058203].es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectCaenorhabditis eleganses_ES
dc.subjectMoltinges_ES
dc.subjectConventional luminometeres_ES
dc.titleMonitoring Caenorhabditis elegans molting in a conventional luminometeres_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.noteThis is an open access article under the CC BY-NC-ND licensees_ES
dadun.citation.publicationNameMethodsXes_ES
dadun.citation.startingPage102235es_ES
dadun.citation.volume10es_ES
dc.identifier.pmid37346480-

Files in This Item:
Thumbnail
File
1-s2.0-S2215016123002327-main.pdf
Description
Size
633.51 kB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.