Quality of life impact of hypoglossal nerve stimulation with inspire (R) device in patients with obstructive sleep apnea intolerant to continuous positive airway pressure therapy
Palabras clave : 
Área de Medicina Clínica y Epidemiología
Quality of life
Obstructive sleep apnea
Hypoglossal nerve stimulation
Minimally invasive surgical technique
EuroQol-5D-5L
Fecha de publicación : 
2022
ISSN : 
2075-1729
Nota: 
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
Cita: 
Baptista-Jardín, P. (Peter Michael); Di Frisco, I. (Isberling Madeleine); Urrestarazu-Bolumburu, E. (Elena); et al. "Quality of life impact of hypoglossal nerve stimulation with inspire (R) device in patients with obstructive sleep apnea intolerant to continuous positive airway pressure therapy". Life. 12 (11), 2022, 1737
Resumen
Patients with obstructive sleep apnea (OSA) that do not tolerate/accept continuous positive airway pressure (CPAP) are candidates for surgical alternatives. Hypoglossal nerve stimulation (HNS) through the implantation of the Inspire (R) device constitutes a minimally invasive operative option. The main objective of this study is to estimate, under real-world clinical practice conditions, the 3-month impact on the quality of life (IQoL) of the HNS in patients with moderate/severe OSA who do not tolerate or accept CPAP, compared to patients who did not receive HNS. As a baseline, the unadjusted EuroQol utility index was 0.764 (SD:0.190) in the intervention group (IGr) and 0.733 (SD:0.205) in the control group (CGr); three months later, the indexes were 0.935 (SD: 0.101) and 0.727 (SD:0.200), respectively. The positive impact on quality of life was estimated to be +0.177 (95% CI: 0.044-0.310; p = 0.010). All dimensions in the IGr improved compared to CGr, especially for usual activities (p < 0.001) and anxiety/depression (p > 0.001). At the end of the follow-up, there was no significant difference in the quality of life between the general Spanish population and the IGr (difference: 0.012; CI95%: -0.03 to -0.057; p = 0.0578) for the same age range; however, there was a difference concerning the CGr (difference: -0.196; CI95%: -0.257 to -0.135; p < 0.001). In conclusion, patients with moderate/severe OSA implanted with the Inspire (R) device showed a positive IQoL.

Ficheros en este ítem:
Vista previa
Fichero
pdf.pdf
Descripción
Tamaño
293.3 kB
Formato
Adobe PDF


Estadísticas e impacto
0 citas en
0 citas en

Los ítems de Dadun están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.