Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Morera-Gómez, Y. (Yasser) | - |
dc.creator | Cartas-Aguila, H.A. (Héctor A.) | - |
dc.creator | Alonso-Hernández, C. M. (Carlos Manuel) | - |
dc.creator | Bernal-Castillo, J.L. (José L.) | - |
dc.creator | Guillén-Arruebarrena, A. (Aniel) | - |
dc.date.accessioned | 2024-01-09T10:04:34Z | - |
dc.date.available | 2024-01-09T10:04:34Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Morera-Gómez, Y. (Yasser); Cartas-Aguila, H.A. (Héctor A.); Alonso-Hernández, C. M. (Carlos Manuel); et al. "Application of the Monte Carlo efficiency transfer method to an HPGe detector with the purpose of environmental samples measurement". Applied Radiation and Isotopes. 97, 2015, 59 - 62 | es_ES |
dc.identifier.issn | 1872-9800 | - |
dc.identifier.uri | https://hdl.handle.net/10171/68219 | - |
dc.description.abstract | Monte Carlo efficiency transfer method was used to determine the full energy peak efficiency of a coaxial n-type HPGe detector. The efficiencies calibration curves for three Certificate Reference Materials were determined by efficiency transfer using a 152Eu reference source. The efficiency values obtained after efficiency transfer were used to calculate the activity concentration of the radionuclides detected in the three materials, which were measured in a low-background gamma spectrometry system. Reported and calculated activity concentration show a good agreement with mean deviations of 5%, which is satisfactory for environmental samples measurement. | es_ES |
dc.description.sponsorship | This research work was undertaken in the framework of the IAEA TC Project CUB/7/008 “Strengthening the National System for Analysis of the Risks and Vulnerability of Cuba's Coastal Zone through the Application of Nuclear and Isotopic Techniques”. The authors will like to acknowledge the EJDS program at ICTP. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | HPGe detector | es_ES |
dc.subject | Monte Carlo | es_ES |
dc.subject | Efficiency transfer | es_ES |
dc.subject | Low-background gamma spectrometry | es_ES |
dc.title | Application of the Monte Carlo efficiency transfer method to an HPGe detector with the purpose of environmental samples measurement | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.identifier.doi | 10.1016/j.apradiso.2014.12.013 | - |
dadun.citation.endingPage | 62 | es_ES |
dadun.citation.publicationName | Applied Radiation and Isotopes | es_ES |
dadun.citation.startingPage | 59 | es_ES |
dadun.citation.volume | 97 | es_ES |
dc.identifier.pmid | 25544663 | - |
Files in This Item:
Statistics and impact
Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.